Eagle ® ICS System – Unicard CR211 User & Installation Instructions Page 3 of 17
Set Password
I
Open the card reader
Press RST button on the
circuit board
Wait for 4 bleep confirmation
Enter a 6-digit code
NB
The following codes are not permitted: 00 00 00, 19 92 00 – 19
92 99
Press #
Wait for 2 short and one long
confirmation bleep
NB
Ensure that you record the number entered
Press *
I
Close the card lock
3. Programming of Cards
Unicard has the capacity to store 98 cards and PIN codes and one
password code. The cards are stored at fixed addresses (101 to
198).
You should make a log of which cards are stored at which address
(a sheet is enclosed at the end of these instructions). Each card
could be combined with one of the following relay functions :-
< 1 > - Relay 1 monostable
(timed)
< 5 > - Relay 2 bistable
(latching)
< 2 > - Relay 2 monostable
(timed)
< 6 > - Relay 1 and relay 2
bistable
< 3 > - Relay 1 and relay 2
monostable
< 7 > - Relay 1 if relay 2 is
activated
< 4 > - Relay 1 bistable
(latching)
< 8 > - Alarm function